BOOKS BY CATEGORY
Your Account
World Congress on Medical Physics and Biomedical Engineering September 7 - 12, 2009 Munich, Germany
Vol. 25/I Radiation Oncology
Price
Quantity
€487.99
(To see other currencies, click on price)
Paperback / softback
Add to basket  

MORE ABOUT THIS BOOK

Main description:

Present Your Research to the World! The World Congress 2009 on Medical Physics and Biomedical Engineering - the triennial scientific meeting of the IUPESM - is the world's leading forum for presenting the results of current scientific work in health-related physics and technologies to an international audience. With more than 2,800 presentations it will be the biggest conference in the fields of Medical Physics and Biomedical Engineering in 2009! Medical physics, biomedical engineering and bioengineering have been driving forces of innovation and progress in medicine and healthcare over the past two decades. As new key technologies arise with significant potential to open new options in diagnostics and therapeutics, it is a multidisciplinary task to evaluate their benefit for medicine and healthcare with respect to the quality of performance and therapeutic output. Covering key aspects such as information and communication technologies, micro- and nanosystems, optics and biotechnology, the congress will serve as an inter- and multidisciplinary platform that brings together people from basic research, R&D, industry and medical application to discuss these issues. As a major event for science, medicine and technology the congress provides a comprehensive overview and in-depth, first-hand information on new developments, advanced technologies and current and future applications. With this Final Program we would like to give you an overview of the dimension of the congress and invite you to join us in Munich! Olaf Doessel Congress President Wolfgang C.


Contents:

Development of New Radioactive Seeds Tm-170 for Brachytherapy.- Implications of Histogram Analysis in Radiation Therapy (HART) Software.- Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes.- Monte Carlo Investigation of Stereotactic Radiosurgery of Spinal Metastases.- Impact of Kilo-Voltage Cone Beam Computed Tomography on Image-Guided Radiotherapy of Prostate Cancer.- Cell Deformation by Dielectrophoretic Fields.- Particle-beam radiation therapy for the tumor of pharyngeal region.- A New Synchrotron Radiotherapy Technique with Future Clinical Potential: Minibeams Radiation Therapy.- Analysis of combined HDR Brachytherapy and external beam radiotherapy in the treatment of carcinoma of cervix.- Motion detection system with three USB cameras and an active search algorithm for stereotactic radiosurgery.- An Investigation of the concomitant doses from Cone Beam CT and CT simulation in Radiotherapy.- Treatment Planning for Volumetric Modulated Arc Therapy (VMAT).- The 21st Birthday Party for intensity-modulated radiation therapy (IMRT); 21 years from 1988-2009; From concept to practical reality.- A Dedicated Irradiation Facility for Radiotherapy Dosimetry.- A beam model applicable to small fields: development and validation.- MR based treatment workflow for external radiotherapy of prostate cancer.- Computational Simulation of Tumour Hypoxia as applied to Radiation Therapy Applications.- Investigation of the Recovery Behaviour as Depending on Parotid Gland Irradiation Dose.- Quality Assurance Program for Radiosurgery at Clinicas Hospital: Results of Implementation.- Application of MRI normoxic polymer gel dosimetry for the evaluation of radiation dose distribution in external beam radiotherapy.- On the Risks of a Constant RBE for Proton Treatment Planning.- Comparison of Dose Distribution in Brain Tumor Conformal Radiotherapy Using CT and CBCT.- Effect of the Same Plan on Doses to Patients during Radiotherapy with Nasopharyngeal Carinoma.- Optimization of Dose Distribution with Multi-leaf Collimator Using Field-in-Field Technique for Radiotherapy of Hodgkin's Lymphoma.- On the performance of monitor chambers to measure the output of medical linear accelerators for high-precision dosimetric investigations.- Calorimetric Determination of Absorbed Dose to Water for an 192Ir HDR Brachytherapy Source in Near-Field Geometry.- The first national IMRT dosimetry inter comparison in Switzerland using a thorax phantom with inhomogeneities.- Calibration of 125I brachytherapy sources in terms of reference air kerma rate.- A Mathematical Aid Decision Tool for RT Planning.- Accuracy of GafChromic EBT Film as Dose Meter in Radiotherapy QA.- Low-Dose Cone-Beam CT Imaging for Radiotherapy.- The realization and application on image pasting for Cone-beam Computed Tomography.- In vivo dosimetry using MOSFET and TLD for Tomotherapy.- Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries.- Editing range compensator for sparing normal tissue in treatment planning of carbon-ion radiotherapy.- A new device for the measurement of the absorbed dose to water for low energy x-ray sources used in brachytherapy.- Comparison of PET Concepts for Dose Delivery Monitoring of Particle Therapy.- Image-guided stereotactic body radiation therapy using a low-Z target imaging beam line and a high dose rate unflattened beam.- Conformity of brain lesions treated with radiosurgery and fractionated stereotactic radiotherapy.- Comparing pencil-beam generated and Monte Carlo generated dose-to-water and dose-to-tissue distributions for proton therapy patients.- In Vivo Evaluation of Photofrin II Radiosentisitivity for the Treatment of Adenocarcinoma Tumors in Balb-C Mice using Brachytherapy.- Extend Distance Treatment for Stereotactic Body Radiation Therapy of Lung Cancer.- Monte Carlo dosimetry with PENELOPE code of the VariSource VS2000 192Ir high dose rate brachytherapy source.- Energy Dependence Investigations of GafChromic EBT Films for Pretreatment Dosimetric Verification of IMRT Plans.- Design and fabrication of the control part of a prototype multileaf collimator system.- Quantitative Evaluation of Gating Radiotherapy System and Dynamic Tumor Tracking Radiotherapy System Developed at KIRAMS.- Dosimetrical Aspect of CT Simulation Role in Radiation Therapy Planning.- Implantable in vivo Dosimetric Probe Based on GaN Radioluminescence.- Pre-clinical experiments in the deep-seated tumor heavy-ion therapy terminal at HIRFL-CSR.- Second source model of collimator scatter and spectra of proton beams.- Determination of nuclear cross sections of proton beams by the collective model and extended nuclear-shell theory.- 4D Monte Carlo Dose Calculations for Particle Therapy Combined with the Spring Network Model of Lung Motion.- Prognostic Analysis of Three-Dimensional Conformal Radiotherapy of Regional Lymph Node Metastasis of the Surgical Esophageal Carcinoma Patients After Resection.- Quality control of brachytherapy source using MCNP5 calculation and radiochromic films measurement.- A Monte Carlo Study of the Particle Angular Distributions from the Electron Applicators of a Medical Linear Accelerator.- Four-Dimensional Computerized Tomography (4D-CT) Reconstruction Without an External Breath Surrogate.- Usefulness of GafChromic EBT film for dosimetry beyond 8.0 Gy.- Influence of the CT slice thickness on the dose calculation for stereotactic treatment planing.- "F-MRI: a method to assess therapy-induced cognitive impairment?".- Revaluation for problem of clinical particle therapy in cell biological effects of proton, carbon-ion and X-ray at Hyogo Ion Beam Medical Center.- Fast and Accurate Proton Computed Tomography Image Reconstruction for Applications in Proton Therapy.- Patient setup using a 3D laser surface scanning system.- Therapy Optimization Based on Non-linear Uptake of PET Tracers versus "Linear Dose Painting".- Ant colony algorithm implementation in commissioning radiosurgery photon beams for Monte Carlo treatment planning.- Respiratory Training and Guiding System using Head Mount Display Device to improve the regularity of breathing.- The use of aSi EPID for in vivo dosimetry in photon beams: clinical experience.- Response of Lithium Formate EPR Dosimeters at Photon Energies Relevant to Brachytherapy.- Development of IMRT Treatment Planning System.- An Investigation on the Internal Wedge Factor Estimation for an Elekta Linac using Monte Carlo Simulation.- Three Dimensional Gamma-Index Analysis and Considerations of the Reference Level Definition for Dosimetric IMRT Plan Verification with 2D Ionisation Chamber Arrays.- Parameterisation of Small Photon Fields in Off-Axis Regions for the SIEMENS 160 MLC.- Suitability of the MVCT of TomoTherapy and Siemens Oncor for Treatment Planning.- Measurement of Absorbed Dose to Water of a Gamma Knife Type C.- On line neutron dose evaluation in patients under radiotherapy.- Lorentz function convolution kernel of narrow photon beam profiles in homogeneous and inhomogeneous media.- FIRST ASSESSMENT OF A NOVEL IGRT DEVICE FOR STEREOTACTIC BODY RADIATION THERAPY.- Heavy Ion Radiotherapy for Shallow-Seated Tumors at IMP.- Density response characteristics of GafChromic EBT dosimetry film using ultraviolet light exposure.- Fiducial-free spinal radiosurgery: Patient motion and targeting accuracy in 227 single fraction treatments with the Cyberknife.- Electron arc planning on the commercial radiation treatment planning system.- Influence of Modulation Restriction in Inverse Optimization with HIPO of Prostate Implants on Plan Quality: Analysis Using Dosimetric and Radiobiological Indices.- Improving the performance of direct Monte-Carlo optimization for large tumor volumes.- Finite Element-Based Biomechanical Modeling of the Bladder for Image Guided Radiotherapy.- Verification of the accuracy in patient alignment using a laser-optical 3D-surface imaging system.- LDR and HDR intracavitory brachytherapy of cancer cervix uterus- rectal doses and ERD comparison.- Evaluation on Lung Cancer Patients' Four-dimensional Treatment Plans Utilizing Biologically Effective Uniform Dose.- Brachytherapy seed localization via iterative forward projection matching (IFPM) algorithm using intraoperative cone-beam-CT sinogram projections.- Using Correlated Sampson to Accelerate CT-Based Monte Carlo Dose Calculations for Brachytherapy Treatment Planning.- Investigation of a stereoscopic camera system for gated radiotherapy.- Extracting breathing traces from any cone-beam image-set.- A linear implementation of dose-volume constraints for multi-criteria optimization.- Monte Carlo Dose Calculation for Radiotherapy Treatment Planning: Dose to Water or Dose to Medium?.- Comparison of Contra lateral Breast & Chest wall doses during Radiotherapy of Ca-Breast (with mastectomy) using Co-60 machine and 6 MV LINAC..- The integration of the dose-guided radiation therapy process on a clinical workstation.- First experience with patient oriented Rapid Arc treatment plan verification.- EGSnrc Monte Carlo-aided dosimetric studies of the 192Ir microSelectron v2 HDR brachytherapy source.- Motion management in scanned particle therapy: beam gating & tracking.- Quality assurance and application of a 4D in vivo dosimetry system using a deformable lung phantom.- Dosimetric advantages of Stereotactic IMRT of brain lesions delivered with a micro-multileaf collimator.- In vivo measurements of the dose delivered by kilovoltage cone-beam CT during prostate radiation therapy.- Initial application of a geometric QA tool for integrated MV and kV imaging systems on Trilogy, Synergy, and Vero.- A New Electron IMRT Technique for Breast Cancer: Comparison to Photon IMRT and Conventional Irradiation Based on Static and Dynamic Dose Measurements.- TLD Correction Factor for Dose Delivery Verification on Gamma Radiation Cobalt-60 on Clinical Treatment.- Development of Treatment Planning System in Peking University.- Direct Monte-Carlo optimization (DMCO) with biological, physical and hybrid objective functions.- 4D calculation and biological dosimetry of the RBE-weighted dose for scanned carbon ion beam therapy.- Radiobiological analysis of planned and delivered IMRT dose distributions.- Impact of Truncation Correction in Flat-Detector Computed Tomography on Carbon Ion Radiotherapy Treatment Planning.- Reconstruction of portal images from IMRT fields for patient setup verification.- Comparison of IMRT and photon-electron-mix technique in radiotherapy treatment planning of ablatio mammae.- Relative peripheral dose at IMRT- A comparison between Siemens Oncor and Artiste.- EPID calibration method for transit in-vivo dosimetry.- Guided radiotherapy by an in-vivo dosimetry for lung tumors.- Implementation of a complete IMRT QA program and clinical experience with the DAVID chamber for in-vivo verification of IMRT deliveries.- Enhancing the error detection capability of the DAVID system with the use of adaptive warning and alarm levels.- PDD AND DOSE PROFILE FOR NARROW BEAMS OF A COBALT - 60 THERAPY UNIT TO BE USED IN STEREOTACTIC RADIOSURGERY.- Technical accuracy of a beam tracking system for scanned particle therapy of intra-fractionally moving targets.- A Joint Research Project to improve the accuracy in dosimetry of brachytherapy treatments in the framework of the European Metrology Research Programme..- Proposals for a ICRU-50/62 -Consistent Dose Prescription Suited for IMRT Radiation Techniques.- Fast Dose Calculations in Radiation Therapy with GPUs.- Robust Radiobiological Optimization for Proton Therapy Treatment Planning.- Neutron Therapy at the FRMII - Calculation of Dose inside a Voxel Phantom.- Monte Carlo based independent monitor unit calculation in IMRT.- Suggestion for an extended quality assurance in 4D CT and its function in gated radiotherapy using a motion phantom.- On-line compensation of dose changes introduced by tumor motion during scanned particle therapy.- Feasibility Study of the Use of Artificial Neural Networks in Predicting Acute Rectal and Urinary Bladder Toxicity Following Prostate Cancer Radiotherapy.- Imaging QA Program for Image Guided RadioTherapy (IGRT).- Dose QA Using EPID and a Dose Prediction Algorithm Independent of the Planning System.- Investigation of the Dose Distribution Quality Achievable with Arc-Modulated Cone Beam Therapy.- Investigating the Reproducibility of Motion for Lung Tumours Treated with Stereotactic Body Radiotherapy.- A Feasibility Study on Multi Prompt-Gamma-Ray Telescope System for Boron Neutron Capture Therapy.- Measurement of Inter-fraction Changes in Bladder Volume Using Ultrasound Image Guidance for Gynecological Radiotherapy.- A comparison of dose and energy-based mapping methods for 4D Monte Carlo dose calculation in deforming anatomy.- IGRT and its Quality Assurance at the DKFZ.- Implementing Volumetric Modulated Arc Therapy (VMAT): Initial Dosimetric Results for Retrospective Patient Study.- Influence of Patient Movement and Anatomy Alteration on the Quality of 3D US-Based Prostate HDR Brachytherapy Treatment.- Clinical Evaluation of an Intra-Modality 3D Ultrasound IGRT System.- Quality assurance of a robotic, image guided radiosurgery system.- Impact of Beam Alignment on Leakage of the Siemens 160 MLCTM.- Observations of Prostate Intrafractional Motion during External Beam Radiation Therapy.- Imaging motion with a 4-row CT scanner (GE Light Speed RT).- Measurements of the Signal-to-Noise Ratio with "EPID QC Phantom (R)" and "epidSoft 2.0" from PTW.- E-IMRT: a web platform for the verification and optimization of radiation treatment plans..- Tumor Alignment between 4DCT and 4D Cone Beam CT for Irregular Respiratory Patient - a Phantom Study.- Analysis of Error Detection in EPID-Based IMRT Pre-Treatment QA.- Improving the accuracy of entrance dosimetry measurements for dose modeling.- Evaluation of the Twin Chamber Signal Ratio, a Physical Estimate of the Low- Energy Photon Contribution to Dose within Radiotherapy Fields.- Uncertainties of RBE in treatment planning for ion beam tumor therapy: Experimental and modeling aspects.- Efficacy of Cummulative Biological Doses at Various Points of Lymphatic Trapzoid Using Microselectron HDR.- Obtaining information on intra-fraction prostate displacement in radiotherapy determined from pre- and post-treatment kV imaging.- The Investigation of Dosimetric Reduction on Organs at Risk in Nasopharyngeal Carcinoma for Static IMRT Planning.- Dose calculations for clinical proton broad beams by GEANT4.- Use of Nanoparticles in Brachytherapy - An Alternative for Enhancing Doses in Cancer Treatment.- Improvement in dose homogeneity in a patient with sinonasal cancer using nasal accessory.- Implementations and first measurements with Delta4 at the TomoTherapy.- Dedicated treatment planning system for the evaluation of the doses delivered to the whole patient body during radiotherapy.- Dose Verification of Critical Structures in Gamma Knife Radio Surgery of Pituitary Adenoma.- Beam Angle Optimization in Particle Therapy with OptiC.- Camera-based independent couch height verification in radiation oncology.- 4D-CT reconstruction based on body volume change.- Monte-Carlo calculation of beam quality correction factors and comparison with experimental measurements.- Localization of high dose rate 192Ir source during brachytherapy treatment using silicon detectors.- Systematic Studies on the Beam Stability and the Transient Effect of a Siemens ONCOR Impression Accelerator.- The Dosimetric Study of Static MLC Based Electronic Tissue Compensation using In-house Leaf Sequencing Software.- The Monte Carlo Code MCPTV- Dose Calculation in Radiation Therapy with Carbon Ions.- Interfractional Variations of Shape and Impact on Dose of Organs at Risk in Head and Neck Cancer Patients during Helical Tomotherapy.- Experimental determination of the radial dose distribution in high gradient regions from a low dose rate iridium-192 wire sources using EPR imaging.- Dose Evaluation in Medulloblastoma Cancers.- Output measurement for small field photon beams in a sandwiched phantom.- Comparison of Monte Carlo Dose Calculation with Advanced Kernel Methods in External Photon Beam Treatment Planning.- Verification of head & neck IMRT-plans by Monte Carlo simulation.- Optimization of Catheter Position and Dwell Time in Prostate HDR Brachytherapy using HIPO and Linear Programming.- Real-Time Compensation of Target Motion with a Dynamic Multileaf Collimator.- An Augmented Reality Application for Patient Positioning and Monitoring in Radiotherapy.- STATIONARY-GANTRY TOMOSYNTHESIS SYSTEM FOR ON-LINE IMAGE GUIDANCE IN RADIATION THERAPY BASED ON A 52-SOURCE COLD CATHODE X-RAY TUBE.- Dosimetric Errors of TPS Calculations without Correction for Heterogeneity - A Study Using CIRS Thorax Phantom.- Adjustable Prescription Dose: A New Strategy to Improve IMRT Treatment Planning.- Segmented Deformable Registration for Improved Modeling of the Lungs.- Basic investigation of boron neutron capture therapy (BNCT) using novel boron agents and accelerator based neutron source.- Robotic Phantom to Simulate Patient Breathing Motion.- Improved simulation of small electron fields for external beam radiation therapy.- The Feasibility of Goggle Monitor for Respiratory Biofeedback of Patient to Reduce Correlation Error Using Real-Time Tumor Tracking System.- Improved Techniques to Assign Accurate Phase Information Of Respiratory Signals for 4D CT Reconstruction.- Predicting Response in Lung Cancer from FDG-PET Uptake Characteristics.- Determination of Dose Escalation Region in Malignant Brain tumors for Radiation Treatment Planning Based on Apparent Diffusion Coefficient Map.- Backscatter Factors for a Clinical 6 MeV Electron Beam.- Fast optimization of non-coplanar beam angle sets for intensity modulated radiation therapy.- Can a Commercially Available TPS Be Used to Develop VMAT Solutions?.- Considering marker visibility during leaf sequencing for segmental intensity-modulated radiation therapy.- Tomotherapy Quality Assurance (TQA): A Fast and Comprehensive Software Tool.- Monte Carlo Based Suggestion of the Best Choice for Material of a Multileaf Collimator (MLC) and the Required Thickness.- BANG-3 (R) polymer gel dosimetry in Cyberknife.- Production of Ac-225 with Cyclotrons for Generating Bi-213 for Targeted Alpha Therapy.- Development of customized program to generate 2D dose map with high resolution for 120 Leaf MLC.- Development of an image-guided radiation therapy device for precise irradiation of small animal tumors.- A finger leaf design for dual layer MLCs.- Head scatter factor calculation considering characteristics of scattered photon.- Monte Carlo Dose Calculation using GPU-Based parallel processing.- Different simple Models for Optimizing Convergent Beam Multiple Field Irradiation for Stereotactic Treatment Techniques.- Sparing of critical organs in radiotherapy of mediastinal lymphoma.- Evaluation of dosimetric accuracies of gated step-and-shoot IMRT using Dynalog data.- Linear Accelerator Photon Beam Interaction with the Virtual Physiological Human.- Investigation into the Pinnacle SmartArc Module for VMAT Planning.- Why still Multibeam Tomotherapy?.- Comparison of beam data using diode and ion chamber in small field of CyberKnife.- Characterization and Monte Carlo Simulation of Low- and High-Perturbation in-vivo Diode Dosimeters for 9 MV X-Rays.- Development of an Optimized Pencil Beam Algorithm for Radiation Therapy.- How Much Target Average Positions in Thorax Region Change Daily?.- Accuracy evaluation of using MV EPID and / or integrated kV imaging system to locate 3D positions of internal fiducial markers using a Calypso system.- In-hospital neutron autoradiography for Boron Neutron Capture Therapy applications.- of a Breath Gating System in a Clinical Environment.- Computerized Treatment Planning Directives for Adaptive Radiation Therapy Management.- Fast range compensation inside the beam line for beam tracking in particle therapy.- Optimal delivery of DMLC Arc Therapy.- Small Photon Field Dosimetry using Gel.- A Method for Evaluation of Target Point Correction in Fractionated Radiotherapy.- Performance of patient specific margins derived using a Bayesian statistical method.- Combination of External/Image-Based Detection of Respiratory Induced Motion and Adaption with a Gating Mechanism.- How Regular Motion Pattern and Patient Individual Respiration Curves Affect Contour and Volume of Geometric Structures in a 4D CT.- Comparison of Daily Online Ultrasound and MV-CBCT Localization Data for Post Prostatectomy Cancer Patients and Implications for PTV Margin Expansion.- Comparison of Localization Techniques for Prostate Radiotherapy.- Optimized Spinal Cord Contour Propagation for Fractionated Radiation Therapy Planning.- A comprehensive quality assurance Program for radiotherapy using TLD : The Algerian Experience.- Optimization of an external beam radiotherapy treatment using GAMOS/Geant4.- Simplified Geometrical Model for Treatment Margins Evaluation in Brain Radiosurgery.- Characterization of a PMMA embedded extrapolation chamber in 60Co gamma beams.- Comparison of different evaluation programs for the verification of patient irradiations with tomotherapy.- Monte Carlo simulation of novel procedures for highly conformal percutaneous radiation with keV-photons for tumor treatment in skin proximity.- Monte Carlo benchmarking of a CCC-based treatment planning system in case of irregularly shaped fields.- Radioiodine Biokinetics and Dosimetry in Patients with Differentiated Thyroid Carcinoma and Renal Insufficiency.- Developments in MRI-based radiation treatment planning.- Electron beam dosimetry in heterogeneous phantoms using MAGIC normoxic polymer gel.- Dosimetric Testing of a New Release of 3D Treatment Planning System with the IAEA-TECDOC-1540.- Absorbed Dose Reference for LDR Brachytherapy the LNE-LNHB Approach.- Image enhancement techniques allowing observation of intra-fractional motion in IMRT treatment for prostate carcinoma.- DIRART - A Software Suite for Deformable Image Registration and Adaptive Radiotherapy Research.- An Alternative Approach to Inverse Planning Optimization: Applying the Projection Theorem to Concave and Convex PTVs for VMAT Delivery.- 3 Years of Data Collection and Analysis of Film Flatness and Symmetry Using Vidar/RIT Software from Different Centers Nation Wide.- Small Field MV Photon Dosimetry.- Virtual Spirometry: Utilizing an abdominal bellows system for quantitatively gating in 4D CT acquisition.- In vivo dosimetry for patient specific quality assurance in aperture based IMRT.- Validation of a Biplanar Diode Array Dosimeter for Helical Tomotherapy Delivery QA.- Comparison between Clinically Used Irregular Fields Shaped by Cerrobend Blocks and by Multileaf Collimator Using a Clarkson Sector Integration Computer Program.- Evaluation of 3-D Treatment Plans Using Physical and Motorised Enhanced Dynamic Wedges.- Integral Dose in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy.- Extension of Electron Monte Carlo Dose Calculation in Eclipse to Siemens Linear Accelerators.- Current Status of the HIBMC, Providing Particle Beam Radiation Therapy for More Than 2,600 Patients, and the Prospects of Laser-Driven Proton Radiotherapy.- Monte Carlo Study of Depth Dose Calculation for Low Energy Clinical Electron Beams.- Setup Variations and Tumor Margins Using the ExacTrac X-Ray 6D in Prostate Radiotherapy.- Useful Techniques for Tomotherapy Treatment Planning.- Optimization of Radial Dose Function for Varian Ir-192 Brachytherapy Source Model VS2000.- On the Use of a Light Ion Kernel for Biologically Optimized Adaptive Inverse Treatment Planning.- Range, Setup and Dose Calculation Errors in IMPT and Their Interrelation.- Motion-Weighted Dose-Volume Histograms - A Novel Approach to 4D Treatment Planning.- Assessing Correlations between the Spatial Distribution of Dose to the Rectal Wall and Late Rectal Toxicity after Prostate Radiotherapy.- Design and Physical Properties of an IrisTM Collimator for Robotic Radiosurgery.- Evaluation of the Clinical Utility of an IrisTM Collimator Combined with a Sequential Optimization Algorithm for Robotic Radiosurgery.- A Quality Assurance Tool Based on kV- and MV-Image Analysis for a Linear Accelerator Including an Integrated IGRT System.- MRI and CT Slice Thickness Evaluation by Computerized Dedicated Procedures.- Re-planning for Compensator-Based IMRT with Original Compensators.- Single-Pulse-Resolved Dosimetry with Miniaturized Detectors in Teletherapy.- The evaluation of therapeutic effect of trastuzumab labeled 177lu in breast cancer cell line.- SURE-LET and BLS-GSM wavelet-based denoising algorithms versus linear Local Wiener Estimator in Radiotherapy portal image denoising..- Learning from Incidents in Radiation Treatment.- Combined Dose Distribution for the External Beam Whole Breast Irradiation and MammoSite Breast Brachytherapy: Monte Carlo Investigation.- In-vivo Proton Beam Shaping Using Static Magnetic Field for Cancer Therapy.- A Preliminary Study on Development of QA System for Stereotactic Head Frame and Its Reliability and Accuracy.- Performance and Clinical Trial in vivo of a Scintillation Dosimeter in Brachytherapy.- Algorithm Development of Designing a Patient-Specific Block for MC-Based Dose Calculation in Electron Beam Therapy for Breast Cancer.- An Air Core Scintillation Dosimeter for Megavoltage External Beam Dosimetry: Experimental Results.- An Air Core Cerenkov Free Scintillation Dosimeter: Monte Carlo Simulation for External Beam Radiation Therapy.- Simulation Study on Coverage of Tumor Motion Accordance with the Scanning Time in Slow-Scan CT.- Calibration of Therapy-level Dosimeters in Japan by Association for Nuclear Technology in Medicine (ANTM).- Out-of-Treatment Room Set-Up for Patient Positioning in External Beam Radiotherapy.- Application of 2 Step IMRT to Spinal Tumors: A Preliminary Retrospective Planning Study Comparison with Classical IMRT.- Comparison of Two different Methods for describing the geometry of a Voxelized Anthropomorphic Phantom in Radiotherapy Treatment Plans.- Measuring system for testing the mechanical isocenter accuracy of medical linear accelerators.- Validation of the SUV values calculation in the iPlan 4.0 Treatment Planning System (BrainLAB).- New system for TBI with translation method at the Institute of Oncology Ljubljana.- Estimation of Free Electron Fraction Value p for a Parallel-Plate Ionization Chamber in High Dose Per Pulse IORT Electron Beams.- VMC++: Validation of the Monte Carlo code for low energies.- Dose Distribution Depending on the Number of Control Points in Forward-Planned Intensity-Modulated Radiation Therapy for Breast Cancer.- Method of Combined Proton-Photon Radiation Therapy of Prostate Cancer.- Conversion of Greyscale Intensity Values from CBCT Images Acquired on Elekta XVI to HU for Treatment Planning Dose Calculations.- Dosimetric Comparison between Helical Tomotherapy and Biologically Based IMRT Treatment Planning System for Selected Cases.- Study of a CVD diamond detector for absorbed dose measurement in photon beams with small field sizes.- Analysis of Dose Shifts induced by Organ Movements during Treatment with TomoTherapy using a Motion Phantom and GafChromic EBT Films.- Tolerance of the Spinal Cord to Hypofractionated Radiotherapy Based on a Generalized Biological Effective Dose (gBED) Model.- Reproducibility of neutron activated Sm-153 in tablets intended for human volunteer studies.- Sequential Optimization Scripts to Facilitate Treatment Planning for Robotic Radiosurgery Clinical Studies for Prostate and Lung Cancers.- Comparative study between IBT or EBRT boost doses at organs at risk in Cervical Cancer treatment.- Beam Characterization for Step-and-Shoot IMRT.- Assessment of Image Guidance Using kV Orthogonal Images and Cone Beam CT for Liver Stereotactic Radiosurgery.- Dosimetric Effects of Gantry Angular Acceleration and Deceleration in Volumetric Modulated Radiation Therapy.- Evaluation of Multileaf Collimator Effect on the Build-Up Dose Region Using Different Ionization Chambers.- Standard Absorbed Dose to Water for HDR Brachytherapy Sources with Fricke Dosimetry.- Monoscopic Imaging for Intra-fraction Motion Management.- Clinac Performance: Watching the First Seconds.- Accelerated Dose Calculation Engine for Interstitial Brachytherapy.- Updated Beam Parameters for Monte Carlo Simulation of Five Varian Megavoltage Photon Beams (4, 6, 10, 15 and 18 MV).- Single and Multibeam Dose Distribution for Treatment Planning of Cancer.- Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): Clinical Use.- The Lessons of QUANTEC (Quantitative Analysis of Normal Tissue Effects in the Clinic): Recommendations for Reporting and Gathering Data on Dose-Volume Dependencies of Treatment Outcome.


PRODUCT DETAILS

ISBN-13: 9783642034725
Publisher: Springer (Springer-Verlag Berlin and Heidelberg GmbH & Co. K)
Publication date: October, 2009
Pages: 1112
Weight: 2823g
Availability: Available
Subcategories: Biomedical Engineering
Related books
From the same series

CUSTOMER REVIEWS

Average Rating